Types of Commercial Tile Installation


tile5

Commercial Tile Installation in Michigan area. Ceramic tile installations in business cooking areas require special factor to consider. Aspects exist in these settings that can add to the degeneration of ceramic floor tile replacements, as well as LATICRETE manufactures specific kinds of items that
can assist in reducing many of the troubles associated with these installations. The floor tile, cement, thin-set, and also the substrate are usually under attack from bacteria, food acids, rough chemical cleaners, aggressive cleaning strategies, and also disinfectants.
Area temperature levels vary frequently and the real-time lots of individuals and tools traveling around the room places consistent stress on the replacement. Lately, there has actually been a boosting pattern towards making use of non-rinse, enzymatic degreasers
that might also have an adverse affect on many epoxy grouts utilized in commercial kitchens.
The very best recommendation for floor tile replacement products is to use mortars and also cements that are high in compressive and also shear bond strengths, tons bearing and immune to severe chemicals. Making use of waterproofing as well as anti-fracture membranes is likewise recommended. HYDRO BAN ®
. or 9235 Waterproofing Membrane layer will shield the substrate from being saturated with. water, microorganisms as well as cleansing options as well as assist to protect the ceramic tile by preventing cracks in the substratum from moving.
through the tile installment.
The techniques of replacement differ a little depending upon the substrate. Thick bed mortar setups enable the floor tile.
specialist to mount the floor tile at the defined altitude and to develop appropriate join in the floor which allow all water and also.
cleaning solutions to take a trip to stream to drains.

Thick-Bed Installation over concrete:.

1. For the thick bed mortar use 3701 Fortified Mortar Bed; or, 226 Thick Bed Mortar mixed with 3701 Mortar.
Admix. For bonding the thick bed mortar use a slurry bond coat made from 254 Platinum (see LATICRETE TDS.
143 – Slurry Bond Coats– When and also Exactly what To Use †.).
See LATICRETE ®. Implementation Declaration F134 * – Concrete – Chemical Resistant Thick Bed – Industrial Grout.
For non-bonded thick bed installation the thick bed mortar have to be a minimum of 2″ (50mm) thick, reinforced.
with 16 scale, 2″ x 2″ (50 mm x 50mm) welded, galvanized cord net to ensure appropriate toughness and longevity.
See LATICRETE Execution Statement F114 * – Concrete – Unbonded Thick Bed with Epoxy Cement.

2. For both waterproofing and anti-fracture security, install HYDRO RESTRICTION or 9235 Waterproofing Membrane.
directly to the mortar bed. 3701 Fortified Mortar Bed; or, 226 Thick Bed Mortar combined with 3701 Mortar Admix.
should dry for a minimum of 72 hrs. @ 70ºF (21 ° C )before installing the membrane layer.

3. Floor tile could be mounted straight to the HYDRO RESTRICTION ®
. or 9235 Waterproofing Membrane with 254 Platinum, or, for.
locations where a more chemically immune adhesive is needed, use LATAPOXY ®
. 300 Adhesive and enable to.
harden.

4. Grout using SPECTRALOCK ®

2000 IG. Thin-Set Installment (over pre sloped concrete or healed mortar bed):.
1. For both waterproofing and anti-fracture defense, set up HYDRO BAN ®. or 9235 Waterproofing Membrane layer.
straight to the concrete. Concrete should treat for a minimum of 14 days and also have an optimum amount of dampness. that does not surpass 5 lbs./ 1,000 ft2./ 24 Hr (2.3 kg/92.3 m2. / 24 Hr) as tested per ASTM F1869 or less than 75 %.
RH as determined with moisture probes before setup. 3701 Fortified Mortar Bed; or, 226 Thick Bed Mortar.
combined with 3701 Mortar should treat for a minimum of 24 hrs. @ 70ºF (21 ° C )prior to mounting the membrane layer.
Setup of Floor tile in.
Office Cooking areas.
TDS 160.

2. Floor tile may be set up directly to the HYDRO RESTRICTION ®. or 9235 Waterproofing Membrane with 254 Platinum, or, for.
locations where a much more chemically immune adhesive is essential, use LATAPOXY ®. 300 Adhesive and allow to.
harden.

3. Grout utilizing SPECTRALOCK ®.
2000 IG.
See LATICRETE Execution Statement F133 * – Concrete – Chemical Resistant Thin Bed.
Thick-Bed Installment (over Outside Glue Plywood substrate).
An exterior adhesive plywood substratum need to have a minimum of 2 layers of 5/8″ (16mm) thickness each (1 1/4″ [32mm] total.
thickness). Flooring systems, including the framing system and also sub-floor panels, over which ceramic tile will be set up will be in.
uniformity with the International Building ordinance (IBC) for commercial applications, or applicable building ordinance. For.
even more info on wood flooring building needs see TDS 152 – Bonding Ceramic Floor tile, Stone or Brick Over.
Wood Floors †.
or for deflection needs see TDS123 – Deflection †.

1. Directly over the exterior adhesive plywood loose lay a cleavage membrane (4 mil polyethylene or 15 lb home builders looked).
and also mount the thick bed mortar comprised of 3701 Fortified Mortar Bed; or, 226 Thick Bed Mortar combined with.
3701 Mortar Admix directly over the cleavage membrane. The thick bed mortar should be a minimum of 2″ (50mm).
thick and reinforced with 16 scale, 2″ x 2″ (50mm x 50mm) bonded, galvanized cable net to ensure proper.
strength and resilience.

2. For both waterproofing and also anti-fracture defense, set up HYDRO RESTRICTION or 9235 Waterproofing Membrane layer.
directly to the mortar bed. 3701 Fortified Mortar Bed; or, 226 Thick Bed Mortar mixed with 3701 Mortar need to dry.
for a minimum of 72 humans resources. at an area temperature level of 70ºF (21 ° C) prior to mounting the membrane layer.

3. Tile may be mounted straight to the HYDRO BAN or 9235 Waterproofing Membrane with 254 Platinum, or, for locations where a more chemically immune adhesive is required, make use of LATAPOXY 300 Adhesive and also enable to.
harden.

4. Grout making use of SPECTRALOCK 2000 IG.
SPECTRALOCK 2000 IG is the excellent selection for usage in an industrial cooking area setup because of its severe chemical.
resistance and also capability to manage heats and aggressive cleansing regimens. SPECTRALOCK 2000 IG surpasses.
ANSI A118.3 and also ANSI A118.5 specifications yet may not be resistant to enzymatic/no rinse kind degreasers and cleaners.

Contact us to get a free tile installation quote today!